Wear indicated replacement of hoist chains

When to change?

  • if the average wire diameter dm has been reduced due to wear by more than 10% of the nominal thickness at any point on the chain link.
  • if the average wire diameter dm does not exceed a value of 0.9d. The calculation bases on the measured of two individual values d1 and d2 which are rotated through 90° ( dm=(d1+d2):2<=0.9d)
  • if a single chain link is permanently lengthened or if the inner pitch t of the an individual link has increased in size by more than 5% as a result of wear.
  • if the inner pitch 11t has increased in size by more than 2% (electric chain hoist) or 3% (manual chain hoist) along a measuring section of 11 chain links as a result of wear.
To the RUD limit gauge ►

Contact the RUD Team!

Please use the contact form for further questions about our products and service features.
Our Team will be pleased to help you. Just call us or send us an e-mail.